PREVENTATIVE MAINTENANCE PROGRAMS

ENSURING OPTIMAL PERFORMANCE: THE VITAL ROLE OF WELL-MAINTAINED BACKUP GENERATORS

Unexpected power outages can lead to significant losses in productivity, revenue, and even cause equipment damage. This highlights the critical importance of maintaining a well-serviced generator.

​

Regular generator maintenance guarantees that your backup power source is operational when needed and also extends the lifespan of your equipment while minimizing the risk of unexpected breakdowns.

​

We offer a comprehensive range of maintenance program options specifically designed to meet the stringent requirements of the Canadian Standards Association (CSA).

PEACE OF MIND THROUGH RELIABLE POWER

For over 20 years, Paramount Power Systems has been at the forefront of providing extensive generator servicing and repair solutions for industrial and commercial clients across Ontario.

​

Our Preventative Maintenance programs are meticulously designed to fully comply with Tables 2 through 6 of CSA Standard C282-19 and are executed by our highly trained and certified technicians.

​

Our experienced professionals utilize the latest technology to diagnose and resolve any issues, ensuring that your generator is in peak condition and ready to manage any power disruptions.

engineering team
1f.png
WEEKLY VISUAL INSPECTIONS

FULFILLS TABLE 2 REQUIREMENTS - Inspect Fuel System (Gaseous or Diesel) for fuel leaks and adequate supply (2 Hours Minimum) including storage tank if equipped - Confirm Operation of the Diesel Fuel Pump (if Equipped) - Check the Engine Oil Lube level and evidence of leaks - Check the Engine Cooling System for adequate coolant levels, evidence of leaks, and unobstructed ventilation Check the Engine Starting System (All Batteries, Battery Charger, and Starters) - Check the Generator Room Condition (Normal and Emergency Room Lighting, Temperature, and Overall Cleanliness) - Check the Transfer Switch(es) Room Condition (Normal and Emergency Room Lighting, Temperature, and Overall Cleanliness) - Check and Inspect the Engine Heaters, drive and fan belts, and engine hoses for operation and evidence of leaks - Confirm the Generator Controller Status is Normal and in AUTO Mode - Record Run Hoursa

2.png
MONTHLY VISUAL INSPECTIONS

FULFILLS TABLE 3 REQUIREMENTS This package includes all of the components included in the previous package - Perform and Record once every Month (Once in conjunction with the Semi-Annual PM Service and Once with the Annual PM Service) - All Services described in Weekly Inspections, PLUS - Confirmation the Battery Charger operates normally - Inspection of the AC alternator - Perform building load test for 60 Minutes to confirm generator, ventilation, and Automatic Transfer Switch(es) operate normally - Check Exhaust system, Exhaust Pipe Insulation, and drain condensation - Record Run Hours Note: The C282 Code requires qualified trained technicians to perform the Semi-Annual services to the emergency power generators utilized for life safety systems.

3.png
SEMI-ANNUAL PREVENTATIVE MAINTENANCE SERVICE

FULFILLS TABLE 4 REQUIREMENTS This package includes all of the components included in the previous two packages - Perform every 6 months (once in conjunction with the Annual PM Service) - Includes the Services described in the Monthly and Weekly Services - Check the Engine linkages, breathers, and governor operation and lubrication as needed - Confirm the proper operation of protective devices - Performance Test on all engine starting batteries Note: The C282 Code requires qualified trained technicians to perform the Semi-Annual services to the emergency power generators utilized for life safety systems.

4.png
ANNUAL PM SERVICE

FULFILLS TABLE 5 REQUIREMENTS This package includes all of the components included in the previous three packages - Performed once every 12 Months - Includes the Services described in the Semi-Annual, Monthly, and Weekly Inspections, PLUS - Confirm operation of breaker(s), voltage regulator, and engine governor - Change the engine oil, oil filters, fuel filters, and tank filters - Lubricate components as required - Check condition of the diesel fuel - Check control wiring and panels - Complete a 2-Hour 100% full generator load capacity test with a resistive load bank - Thermal survey of cable connections on breaker and transfer switches Note: The C282 Code requires qualified trained technicians to perform the Annual services to the emergency power generators utilized for life safety systems.

5.png
QUINQUENNIAL SERVICE

FULFILLS TABLE 6 REQUIREMENTS This package includes all of the components included in the previous four packages - Performed once every FIVE years - Inspect AC alternator windings and complete the winding resistance test (meggar) - Flush Coolant System and replenish the coolant with appropriate antifreeze - Replace the engine coolant thermostat(s) - Inspect engine valve clearance and adjust as required - Infrared Thermal Imaging assessment of generator breaker and ATS connections Note: The C282 Code requires qualified trained technicians to perform the Quinquennial services to the emergency power generators utilized for life safety systems.

24/7 EMERGENCY SERVICES

Our Emergency Services are legendary, so if your backup power generator fails to activate when you need it, rest-assured our team of experienced technicians are on standby, day and night when you call 1-877-603-0724.